Tasha Energy

Showing 17–24 of 62 results

  • 435,000.00

    168L Solar Chest Freezer

    Power: DC 12v/24v; AC 220 – 240v
    Refrigerant: R600a/R134a
    With AC/DC Adapter, Lock Key, glass
    Light and Outdoor Condenser Unit.

  • 40,000.00

    180W Solar Panel

    Specifications
    ● Module Type: 180W
    ● Rated Maximum Power (Pmax): 180W
    ● Voltage at Pmax (Vmp): 19.7V
    ● Current at Pmax(imp): 9.14A
    ● Open-Circuit Voltage (Voc): 23.64V
    ● Short-Circuit Current (isc): 10A
    ● Maximum System Voltage: 1000V
    ● Maximum Series Fuse Rating: 20A
    ● Safety Class: CLASS A
    ● Weight: 8.5kg
    ● Dimension: 1125*770*25mm

  • 135,000.00

    1KVA 12V Hybrid Inverter

    Specifications

    MODEL: TE-1.0K12
    Rated Power: 1000VA/1000W
    AC INPUT: Voltage230 VAC
    Selectable Voltage Range: 170-280 VAC (For Personal Computers)
    90-280 VAC (For Home Appliances)
    Frequency Range: 50 Hz/60 Hz (Auto sensing)
    AC OUTPUT
    AC Voltage Regulation (Batt. Mode): 230VAC+5%
    Surge Power: 2000VA
    Efficiency(Peak) PV to INV: 98%
    Efficiency(Peak)Battery to INV: 94%
    Transfer Time:10ms
    BATTERY
    Battery Voltage: 12 VDC
    Floating Charge Voltage: 13.5VDC
    Overcharge Protection: 16 VDC
    SOLAR CHARGER & AC CHARGER
    Solar Charger Type:MPPT
    Maximum PV Array Power: 600W
    MPPT Range @ Operating Volt gea: 20-150VDC
    Maximum PV Array Open Circuit:150VDC
    Voltage Solar
    Maximum solar Charging Current: 40A
    Maximum AC Charging Current: 40A
    Maximum Solar+AC Charging Current: 80A
    PHYSICAL
    Carton Dimension, D X W XH(mm): 340*295*145

  • 110,000.00

    1kva 12v Mega Plus Inverter

    Specifications
    BATTERY MODE
    Maximum current load ≤2.0 amp
    Output voltage no load – 220v±7v
    Full load output voltage – 195v-220v
    Output frequency no load full load – 50Hz ±1 Hz
    Full load battery current – 60A±1A
    Fan run should be ok
    MAINS MODE
    UPS MODE
    low cut voltage – 180V±10V
    low cut recovery – 190V±10V
    high cut – 260V±10V
    high cut recovery – 250V±10V
    change over mains to ups- ≤10 ms
    change over ups to mains – ≤30 ms
    NORMAL MODE
    low cut voltage – 100V±10V
    low cut recovery – 110V±10V
    high cut – 280V±10V
    high cut recovery – 270V±10V
    CHARGING MODE MAINSONLY MAINS AVAILABLE
    charging current – 15 amp ±1 amp
    boost charging voltage – 14.4v±0.2v
    PROTECTIONS
    Overload Protection >62 Amp
    Battery Low Alarm 10.5v±0.2v
    Battery Low Shut Down 10.0v±.2v
    Over Temperature Protection 104°c±5°c
    Short Ckts Protection – Should Be Ok
    Mains Mcb Trip – Should Be Ok

  • 200,000.00

    2.5 KVA 24V Mega Plus Inverter

    Specifications

    Pure Sine Wave
    Maximum current load ≤2.0 amp
    Output voltage no load – 220v±7v
    Full load output voltage – 195v-220v
    Output frequency no load full load – 50Hz ±1 Hz
    Full load battery current – 65A±1A
    Fan run should be ok
    MAINS MODE
    UPS MODE
    low cut voltage – 180V±10V
    low cut recovery – 190V±10V
    high cut – 260V±10V
    high cut recovery – 250V±10V
    change over mains to ups- ≤10 ms
    change over ups to mains – ≤30 ms
    NORMAL MODE
    low cut voltage – 100V±10V
    low cut recovery – 110V±10V
    high cut – 280V±10V
    high cut recovery – 270V±10V
    CHARGING MODE MAINSONLY MAINS AVAILABLE
    charging current – 16 amp ±1 amp
    boost charging voltage – 28.8v±0.4v
    PROTECTIONS
    Overload Protection >70 Amp, 6 retries
    Battery Low Alarm 21v±0.2v
    Battery Low Shut Down 20.0v±.2v
    Over Temperature Protection 104°c±5°c
    Short Ckts Protection – Should Be Ok
    Mains Mcb Trip – Should Be Ok

Cart (0 items)