    Specifications
    BATTERY MODE
    Maximum current load ≤2.0 amp
    Output voltage no load – 220v±7v
    Full load output voltage – 195v-220v
    Output frequency no load full load – 50Hz ±1 Hz
    Full load battery current – 60A±1A
    Fan run should be ok
    MAINS MODE
    UPS MODE
    low cut voltage – 180V±10V
    low cut recovery – 190V±10V
    high cut – 260V±10V
    high cut recovery – 250V±10V
    change over mains to ups- ≤10 ms
    change over ups to mains – ≤30 ms
    NORMAL MODE
    low cut voltage – 100V±10V
    low cut recovery – 110V±10V
    high cut – 280V±10V
    high cut recovery – 270V±10V
    CHARGING MODE MAINSONLY MAINS AVAILABLE
    charging current – 15 amp ±1 amp
    boost charging voltage – 14.4v±0.2v
    PROTECTIONS
    Overload Protection >62 Amp
    Battery Low Alarm 10.5v±0.2v
    Battery Low Shut Down 10.0v±.2v
    Over Temperature Protection 104°c±5°c
    Short Ckts Protection – Should Be Ok
    Mains Mcb Trip – Should Be Ok

  • 22%
    Original price was: ₦175,000.00.Current price is: ₦135,000.00.

    2.5KVA 24V Non-hybrid Inverter

  • 22%
    Original price was: ₦265,000.00.Current price is: ₦205,000.00.

    3.5kva 24v Mega Plus Inverter

    Specifications

    Pure Sine Wave
    BATTERY MODE
    Output voltage no load – 220v±7v
    Full load output voltage 180v-220v
    Output frequency no load full load 50Hz ±1 Hz
    Full load battery current 75A±2A
    No load current switch off – <200ma
    Fan run should be ok
    MAINS MODE
    UPS MODE
    low cut voltage – 180V±10V
    low cut recovery – 190V±10V
    high cut – 260V±10V
    high cut recovery – 250V±10V
    high cut – 260V±10V
    change over mains to ups ≤10 ms
    change over ups to mains – ≤30 ms
    NORMAL MODE
    low cut voltage – 100V±10V
    low cut recovery – 110V±10V
    high cut – 280V±10V
    high cut recovery- 270V±10V
    CHARGING MODE MAINSONLY MAINS AVAILABLE
    charging current – 16 amp ±1 amp
    boost charging voltage – 28.8v±0.2v
    PROTECTIONS
    Overload Protection >80 Amp,6 Retries
    Battery Low Alarm – 21v±0.2v
    Battery Low Shut Down – 20.0v±.2v
    Over Temperature Protection – 104°c±5°c
    Short Ckts Protection – Should Be Ok
    Mains Mcb Trip – Should Be Ok

  • 405,000.00

    5kva 48v Pure Sine Wave Inverter

    Specifications
    BATTERY MODE
    Maximum current load – ≤2.2 amp
    Output voltage no load – 220v±7v
    Full load output voltage 180v-220v
    Output frequency no load full load – 50Hz ±1 Hz
    Full load battery current – 80A±2A
    Fan run should be ok
    MAINS MODE
    UPS MODE
    low cut voltage – 180V±10V
    low cut recovery- 190V±10V
    high cut – 260V±10V
    high cut recovery – 250V±10V
    change over mains to ups- ≤10 ms
    change over ups to mains – ≤30 ms
    NORMAL MODE
    low cut voltage – 100V±10V
    low cut recovery – 110V±10V
    high cut 280V±10V
    high cut recovery 270V±10V
    CHARGING MODE MAINSONLY MAINS AVAILABLE
    charging current – 18 amp ±1 amp
    boost charging voltage – 57.6 v±0.2v
    PROTECTIONS
    Overload Protection >85 Amp,6 Retries
    Battery Low Alarm 42v±0.4v
    Battery Low Shut Down 40.0v±.4v
    Over Temperature Protection 104°c±5°c
    Short Ckts Protection – Should Be Ok
    Mains Mcb Trip – Should Be Ok