₦110,000.00
1kva 12v Pure Sine Wave Inverter
Specifications
BATTERY MODE
Maximum current load ≤2.0 amp
Output voltage no load – 220v±7v
Full load output voltage – 195v-220v
Output frequency no load full load – 50Hz ±1 Hz
Full load battery current – 60A±1A
Fan run should be ok
MAINS MODE
UPS MODE
low cut voltage – 180V±10V
low cut recovery – 190V±10V
high cut – 260V±10V
high cut recovery – 250V±10V
change over mains to ups- ≤10 ms
change over ups to mains – ≤30 ms
NORMAL MODE
low cut voltage – 100V±10V
low cut recovery – 110V±10V
high cut – 280V±10V
high cut recovery – 270V±10V
CHARGING MODE MAINSONLY MAINS AVAILABLE
charging current – 15 amp ±1 amp
boost charging voltage – 14.4v±0.2v
PROTECTIONS
Overload Protection >62 Amp
Battery Low Alarm 10.5v±0.2v
Battery Low Shut Down 10.0v±.2v
Over Temperature Protection 104°c±5°c
Short Ckts Protection – Should Be Ok
Mains Mcb Trip – Should Be Ok -
₦200,000.00
2.5 KVA 24V Mega Plus Inverter
Specifications
Pure Sine Wave
Maximum current load ≤2.0 amp
Output voltage no load – 220v±7v
Full load output voltage – 195v-220v
Output frequency no load full load – 50Hz ±1 Hz
Full load battery current – 65A±1A
Fan run should be ok
MAINS MODE
UPS MODE
low cut voltage – 180V±10V
low cut recovery – 190V±10V
high cut – 260V±10V
high cut recovery – 250V±10V
change over mains to ups- ≤10 ms
change over ups to mains – ≤30 ms
NORMAL MODE
low cut voltage – 100V±10V
low cut recovery – 110V±10V
high cut – 280V±10V
high cut recovery – 270V±10V
CHARGING MODE MAINSONLY MAINS AVAILABLE
charging current – 16 amp ±1 amp
boost charging voltage – 28.8v±0.4v
PROTECTIONS
Overload Protection >70 Amp, 6 retries
Battery Low Alarm 21v±0.2v
Battery Low Shut Down 20.0v±.2v
Over Temperature Protection 104°c±5°c
Short Ckts Protection – Should Be Ok
Mains Mcb Trip – Should Be Ok -
-
₦335,000.00
3.5kva 24v Mega Plus Inverter
Specifications
Pure Sine Wave
BATTERY MODE
Output voltage no load – 220v±7v
Full load output voltage 180v-220v
Output frequency no load full load 50Hz ±1 Hz
Full load battery current 75A±2A
No load current switch off – <200ma
Fan run should be ok
MAINS MODE
UPS MODE
low cut voltage – 180V±10V
low cut recovery – 190V±10V
high cut – 260V±10V
high cut recovery – 250V±10V
high cut – 260V±10V
change over mains to ups ≤10 ms
change over ups to mains – ≤30 ms
NORMAL MODE
low cut voltage – 100V±10V
low cut recovery – 110V±10V
high cut – 280V±10V
high cut recovery- 270V±10V
CHARGING MODE MAINSONLY MAINS AVAILABLE
charging current – 16 amp ±1 amp
boost charging voltage – 28.8v±0.2v
PROTECTIONS
Overload Protection >80 Amp,6 Retries
Battery Low Alarm – 21v±0.2v
Battery Low Shut Down – 20.0v±.2v
Over Temperature Protection – 104°c±5°c
Short Ckts Protection – Should Be Ok
Mains Mcb Trip – Should Be Ok -
₦545,000.00
5kva 48v Pure Sine Wave Inverter
Specifications
BATTERY MODE
Maximum current load – ≤2.2 amp
Output voltage no load – 220v±7v
Full load output voltage 180v-220v
Output frequency no load full load – 50Hz ±1 Hz
Full load battery current – 80A±2A
Fan run should be ok
MAINS MODE
UPS MODE
low cut voltage – 180V±10V
low cut recovery- 190V±10V
high cut – 260V±10V
high cut recovery – 250V±10V
change over mains to ups- ≤10 ms
change over ups to mains – ≤30 ms
NORMAL MODE
low cut voltage – 100V±10V
low cut recovery – 110V±10V
high cut 280V±10V
high cut recovery 270V±10V
CHARGING MODE MAINSONLY MAINS AVAILABLE
charging current – 18 amp ±1 amp
boost charging voltage – 57.6 v±0.2v
PROTECTIONS
Overload Protection >85 Amp,6 Retries
Battery Low Alarm 42v±0.4v
Battery Low Shut Down 40.0v±.4v
Over Temperature Protection 104°c±5°c
Short Ckts Protection – Should Be Ok
Mains Mcb Trip – Should Be Ok